What will a 12,000‑watt generator run?

A 12,000-watt generator can start loads up to 12,000 W, but it runs only about 9,600 W — and should carry about 7,650 W for hours. On its own it runs a 3-ton central AC, a heat pump, an electric dryer, an electric water heater and a 1 HP well pump. Together it covers a 3-ton central AC with the fridge and lights, but not central AC on top of all the essentials. Generators this size have a 240 V outlet, so 240 V loads like a well pump can run through a transfer switch.

A 12,000-watt generator at a glance

Starting (on the box)
12,000 W
Running
about 9,600 W
For hours (80%)
about 7,650 W
Outlets
120 V + 240 V

Starting watts vs running watts

On generators this size the number on the box is usually the starting (peak) rating: what the generator can push for a second while a motor starts. A motor needs several times its running power for that moment.[1] What it can keep up is lower — on the 5 models this size in our database, 76% to 81% of the starting rating, which puts a 12,000-watt generator at about 9,600 W running. A few are rated 12,000 W running instead — like the Westinghouse WGen12000 — and handle a little more than this page assumes.

For loads that run for hours, stay under about 80% of the running rating — about 7,650 W — so the generator isn’t working flat out. Check each appliance’s label for its watts; if it lists only amps, multiply by the voltage.[2]

Will a 12,000-watt generator run central air?

Yes. Central AC (3 ton) needs about 3,500 W running and 10,500 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run a heat pump?

Yes. Heat pump needs about 4,700 W running and 9,200 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run an electric water heater?

Yes. Electric water heater needs about 3,900 W running, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run an electric dryer?

Yes. Electric dryer needs about 5,500 W running and 6,400 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run a well pump?

Yes. Well pump (1/2 HP) needs about 1,000 W running and 2,550 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Bigger unit: Well pump (1 HP) needs about 2,000 W running and 6,000 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

What a 12,000-watt generator runs, appliance by appliance

Each appliance on its own, with the typical running and starting watts the calculator uses. Start one motor at a time, and add up everything else that’s running.

Which appliances a 12,000-watt generator runs on their own
ApplianceRunningStartingOn a 12,000-watt generator
Kitchen
Refrigerator700 W2,900 WRuns it
Chest freezer500 W1,500 WRuns it
Upright freezer700 W2,900 WRuns it
Microwave (1,000 W)1,000 W1,000 WRuns it
Coffee maker1,300 W1,300 WRuns it
Toaster1,100 W1,100 WRuns it
Slow cooker250 W250 WRuns it
Dishwasher1,500 W1,500 WRuns it
Electric stove, 8-inch burner2,100 W2,100 WRuns it
Heating & Cooling
Furnace fan (1/2 HP)875 W3,150 WRuns it
Furnace fan (1/3 HP)700 W2,100 WRuns it
Window AC (10,000 BTU)1,200 W2,200 WRuns it
Window AC (12,000 BTU)1,700 W4,200 WRuns it
Central AC (3 ton)3,500 W10,500 WRuns it
Heat pump4,700 W9,200 WRuns it
Space heater1,500 W1,500 WRuns it
Dehumidifier650 W1,950 WRuns it
Box fan150 W300 WRuns it
Ceiling fan75 W75 WRuns it
Water
Sump pump (1/2 HP)1,050 W2,700 WRuns it
Sump pump (1/3 HP)800 W2,100 WRuns it
Sump pump (3/4 HP)1,200 W3,600 WRuns it
Well pump (1/2 HP)1,000 W2,550 WRuns it
Well pump (1 HP)2,000 W6,000 WRuns it
Electric water heater3,900 W3,900 WRuns it
Laundry
Washing machine1,150 W2,800 WRuns it
Electric dryer5,500 W6,400 WRuns it
Gas dryer700 W2,100 WRuns it
Everyday
LED lights (10 bulbs)100 W100 WRuns it
TV (LED 55")150 W150 WRuns it
Wi-Fi router + modem20 W20 WRuns it
Laptop150 W150 WRuns it
Desktop computer + monitor800 W800 WRuns it
Phone chargers25 W25 WRuns it
Security system100 W100 WRuns it
Hair dryer1,500 W1,550 WRuns it
Garage door opener (1/2 HP)700 W1,450 WRuns it
Medical
CPAP (with heated humidifier)120 W120 WRuns it
Oxygen concentrator (5 LPM)350 W1,050 WRuns it

Running several things at once

Everything running together has to stay under about 9,600 W with headroom, and the biggest startup has to fit within 12,000 W. Motors don’t start in the same second, so only the largest jump counts.

12,000-Watt generators in our database

The models in our database rated 11,500 W to 15,000 W starting, which this page’s numbers come from. Specs are from each maker’s official page; the model names link to them. See all generators by size.

Generators near 12,000-watt with their running and starting watts
ModelRunningStarting
Champion · Portable · Dual fuel · 240 V9200W Electric Start Dual Fuel with CO Shield (201302)9,200 W11,500 W
Westinghouse · Portable · Dual fuel · 240 VWGen9500DF9,500 W12,500 W
DuroMax · Portable · Dual fuel · 240 VXP13000EH10,500 W13,000 W
DuroMax · Portable · Tri fuel · 240 VXP13000HXT Tri Fuel10,500 W13,000 W
Westinghouse · Portable · Gasoline · 240 VWGen1200012,000 W15,000 W
Not sure 12,000-watt is enough?
List what you want to run and get the generator size for your whole house.
Open the calculator

Before you plug in

Questions

Is 12,000-watt the running or the starting rating?

Usually the starting (peak) rating. On the generators this size in our database, running watts are 76%–81% of starting watts, so a 12,000-watt generator runs about 9,600 W. Some are rated 12,000 W running instead and handle a little more.

Will a 12,000-watt generator run central air?

Yes. Central AC (3 ton) needs about 3,500 W running and 10,500 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run a heat pump?

Yes. Heat pump needs about 4,700 W running and 9,200 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run an electric water heater?

Yes. Electric water heater needs about 3,900 W running, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run an electric dryer?

Yes. Electric dryer needs about 5,500 W running and 6,400 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Will a 12,000-watt generator run a well pump?

Yes. Well pump (1/2 HP) needs about 1,000 W running and 2,550 W for a second to start, within a 12,000-watt generator. It connects to the 240 V outlet through a transfer switch or interlock installed by an electrician.

Can I connect a 12,000-watt generator to my house?

Never by plugging it into a wall outlet — that backfeeds the grid and can electrocute utility workers. Plug appliances in with heavy-duty outdoor cords, or have a licensed electrician install a power inlet with a transfer switch or interlock, which is also how its 240 V outlet runs hardwired loads.[6]

Sources

  1. U.S. Department of Energy, Motor Systems Tip Sheet #10: Turn Motors Off When Not in Use
  2. Virginia Cooperative Extension, Estimating Appliance and Home Electronic Energy Use
  3. CDC, Carbon Monoxide Poisoning Basics
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center
  5. U.S. Consumer Product Safety Commission, Safety Alert: Portable Generator Hazards
  6. OSHA, Using Portable Generators Safely (Fact Sheet)