Your service size is a ceiling, not a target
The amp rating on your main breaker is the most your service can carry: 200 amps at 240 volts is 48,000 watts. Homes come nowhere near that. The average U.S. household uses about 10,800 kWh of electricity a year, which works out to roughly 1.2 kW on average.[1]
What sets a generator’s size is the load that runs at the same time, plus the single biggest motor start. A 200-amp main breaker no more means you need a 48 kW generator than a 160 mph speedometer means you drive that fast.
- Central AC (3 ton)3,500 W
- Furnace fan (1/2 HP)875 W
- Refrigerator700 W
- Chest freezer500 W
- LED lights (10 bulbs) × 2200 W
- TV (LED 55")150 W
- Laptop150 W
- Phone chargers25 W
- Wi-Fi router + modem20 W
- Takes turns: Electric dryer, the biggest5,500 W
- Startup surge: Central AC (3 ton)+7,000 W
Running 11,620 W → worst moment 18,620 W → generator rated at least 14,525 W.
Three ways to back up a 200-amp home
Essentials only: the fridge, a freezer, the sump pump, the furnace blower, lights and Wi-Fi. That fits a portable generator connected to a few circuits through a transfer switch or interlock.
The whole house with load management: a standby generator on an automatic transfer switch that holds off the central AC, the dryer or the water heater until there’s capacity, so the big loads take turns instead of stacking up.
The whole house, everything at once: the biggest generator and the most fuel. The combinations below show how far the number moves when nothing is allowed to wait.
What about a 400-amp service?
A 400-amp service — 96,000 watts on paper — usually means a large house with two panels, two central AC systems and more electric appliances. The rule is the same: add up what has to run together. Two AC compressors are what push the size up, which is why large homes so often rely on load management.
For any standby generator wired to your panel, an electrician works out the size with a load calculation of everything it will carry and installs a properly rated transfer switch.[2] Most areas also require a permit.
Generators that can run a 200-amp service
The smallest models in our database with at least 14,525 W rated and 18,620 W of starting power, and a 240 V outlet — smallest first. Each model links to its maker’s official spec page. It’s a fit list, not a ranking.
| Model | Rated | Starting |
|---|---|---|
| Generac · Home standbyGuardian 18kW (G0072590) | 18,000 W | — |
| Kohler · Home standby20RCA / 20RCAL | 20,000 W | — |
| Generac · Home standbyGuardian 22kW (G0072600) | 22,000 W | — |
| Briggs & Stratton · Home standbyPowerProtect+ 22kW (040787) | 22,000 W | — |
| Generac · Home standby24kW (G0072610) | 24,000 W | — |
Browse all 10 models that fit. As an Amazon Associate I earn from qualifying purchases.
Common combinations
Motors don’t all start in the same second, so you only add the single biggest startup jump on top of everything that’s running.
- Essentials on a 200-amp service: 3,245 W running, 5,520 W starting → at least 4,057 W rated (mid portable). Open in calculator
- Whole house without central AC: 8,120 W running, 10,395 W starting → at least 10,150 W rated (home standby). Open in calculator
- Same house, nothing taking turns: 21,270 W running, 28,270 W starting → at least 26,588 W rated (home standby). Open in calculator
- 400-amp home with two central AC units: 15,120 W running, 22,120 W starting → at least 18,900 W rated (home standby). Open in calculator
We divide the running load by 0.8 because a generator shouldn’t sit above about 80% of its rating for hours.
How the number adds up
| Appliance | Running | Starting | Runs |
|---|---|---|---|
| Refrigerator | 700 W | 2,900 W | together |
| Chest freezer | 500 W | 1,500 W | together |
| Microwave (1,000 W) | 1,000 W | 1,000 W | takes turns |
| Dishwasher | 1,500 W | 1,500 W | takes turns |
| Electric stove, 8-inch burner | 2,100 W | 2,100 W | takes turns |
| Furnace fan (1/2 HP) | 875 W | 3,150 W | together |
| Central AC (3 ton) | 3,500 W | 10,500 W | together |
| Electric water heater | 3,900 W | 3,900 W | takes turns |
| Washing machine | 1,150 W | 2,800 W | takes turns |
| Electric dryer | 5,500 W | 6,400 W | takes turns |
| LED lights (10 bulbs) × 2 | 200 W | 100 W | together |
| TV (LED 55") | 150 W | 150 W | together |
| Wi-Fi router + modem | 20 W | 20 W | together |
| Laptop | 150 W | 150 W | together |
| Phone chargers | 25 W | 25 W | together |
| Running load | 11,620 W | everything together + the biggest “takes turns” item | |
| Worst startup moment | 18,620 W | running load + Central AC (3 ton) starting (+7,000 W) | |
| Minimum generator | 14,525 W | rated watts (running ÷ 0.8) · how we size | |
How we got the number
Step 1: Add up what runs at once
11,620 W6,120 W running together + Electric dryer at 5,500 W, the biggest item that takes turns
Step 2: Add the single biggest startup
18,620 W+7,000 W for a second when Central AC (3 ton) starts — motors don’t start together
Step 3: Add 25% headroom
14,525 W11,620 W ÷ 0.8, so the generator isn’t pushed above about 80% for hours
Step 4: Pick a class that covers both
Home standby10 kW and up, with enough starting power for 18,620 W
- Small inverterUp to 2,500 W
- Mid portable2,500–5,000 W
- Large portable5,000–10,000 W
- This guideHome standby10 kW and up
Before you plug in
Use an electrician
Transfer switches and interlocks are installed by a qualified electrician.[2]
Questions
What size generator do I need for a 200-amp service?
One sized for what you’ll run, not for 200 amps. Running everything including central AC usually takes a home standby generator, while the essentials fit a portable. The calculator gives the exact number for your appliances.
Do I need a 48 kW generator for a 200-amp panel?
No. 48 kW is the most a 200-amp service can deliver, not what a house uses. With load management, a much smaller standby generator can back up the whole panel.
What size generator do I need for a 400-amp service?
It depends on what runs at once — above all, how many central AC systems the house has. Add both AC units and the rest of your list in the calculator, and have an electrician confirm it with a load calculation.
Can a portable generator power a 200-amp house?
Not all of it at once, but a large portable connected through a transfer switch or interlock can run the essential circuits.[2]