What size generator do I need for a refrigerator and a freezer?

Together these draw about 1,200 W running and 3,400 W at the worst startup moment, so look for a generator with at least 1,500 W rated and 3,400 W starting power — a mid portable (2,500–5,000 W).

CALCULATOR · FRIDGE + FREEZER PRESELECTED

Change it for your house

Change how many you have, mark what can take turns, or add what else has to run. The numbers update as you go.

  • Refrigerator
    700 W run · 2,900 W start
    1
  • Chest freezer
    500 W run · 1,500 W start
    1
ALSO RUNNING IN YOUR HOUSE?

Minimum 1,500 W rated and 3,400 W starting: Mid portable.

1,500 W
MIN. RATED
3,400 W
STARTING
Mid portable2,500–5,000 W
Open the calculator

Your list carries over — add the rest of the house there, edit watts from your labels and see models that fit.

At a glance

Running
1,200 W
Starting
3,400 W
Minimum generator
1,500 W rated
Class
Mid portable
Outlet
120 V outlets
Can take turns?
None — all run together

Two compressors, one startup at a time

A fridge and a freezer each have a compressor that switches on by itself whenever its thermostat calls for cold, and every start is a motor start with a short surge several times its running power.[1] Both stay on “together” in the calculator, because you can’t tell a thermostat to wait.

The two compressors almost never kick on in the same second, though. So the generator needs the running watts of both, plus only the bigger of the two startup jumps — not both surges stacked on top of each other.

What makes up the peak for a refrigerator and a freezer
  • Refrigerator700 W
  • Chest freezer500 W
  • Startup surge: Refrigerator+2,200 W

Running 1,200 W → worst moment 3,400 W → generator rated at least 1,500 W.

Chest freezer, upright freezer or a second fridge

A chest freezer has a small compressor and holds its cold well, so it adds the least. An upright freezer or a second refrigerator in the garage behaves much more like a full-size fridge, with a similar startup surge.

Units in a hot garage work harder in summer, and older ones often draw more than the typical numbers. If yours is old or sits in the heat, check its label and enter your own watts in the calculator.

Keeping food safe through a long outage

Food stays safe longer if the doors stay shut: a closed fridge keeps its cold for hours, and a full freezer for much longer than a half-empty one.[2] You don’t have to run both around the clock — a few hours on, then doors closed, saves fuel.

Plug each one straight into the generator with its own heavy-duty outdoor cord, and keep the generator outside, well away from windows and doors.[3][4]

Generators that can run a refrigerator and a freezer

The smallest models in our database with at least 1,500 W rated and 3,400 W of starting power — smallest first. Each model links to its maker’s official spec page. It’s a fit list, not a ranking.

Generator models that cover a refrigerator and a freezer, linked to their official specs
ModelRatedStarting
Predator · Inverter3500 W Super Quiet Inverter with CO SECURE (71358)3,000 W3,500 W
Champion · Inverter4500W Electric Start Dual Fuel Inverter (201319)3,500 W4,500 W
Champion · Portable3500W Dual Fuel with CO Shield (201296)3,500 W4,375 W
Generac · PortableGP3600 COsense (7722)3,600 W4,500 W
Westinghouse · InverteriGen5000DFc3,900 W5,000 W

Browse all 40 models that fit. As an Amazon Associate I earn from qualifying purchases.

Common combinations

Motors don’t all start in the same second, so you only add the single biggest startup jump on top of everything that’s running.

  • Fridge + upright freezer: 1,400 W running, 3,600 W starting → at least 1,750 W rated (mid portable). Open in calculator
  • Two refrigerators: 1,400 W running, 3,600 W starting → at least 1,750 W rated (mid portable). Open in calculator
  • Fridge + chest freezer + sump pump: 2,250 W running, 4,450 W starting → at least 2,813 W rated (mid portable). Open in calculator

We divide the running load by 0.8 because a generator shouldn’t sit above about 80% of its rating for hours.

How the number adds up

Appliances, running and starting watts for a refrigerator and a freezer
ApplianceRunningStartingRuns
Refrigerator700 W2,900 Wtogether
Chest freezer500 W1,500 Wtogether
Running load1,200 Weverything together + the biggest “takes turns” item
Worst startup moment3,400 Wrunning load + Refrigerator starting (+2,200 W)
Minimum generator1,500 Wrated watts (running ÷ 0.8) · how we size

How we got the number

  1. Step 1: Add up what runs at once

    1,200 W

    2 appliances running together

  2. Step 2: Add the single biggest startup

    3,400 W

    +2,200 W for a second when Refrigerator starts — motors don’t start together

  3. Step 3: Add 25% headroom

    1,500 W

    1,200 W ÷ 0.8, so the generator isn’t pushed above about 80% for hours

  4. Step 4: Pick a class that covers both

    Mid portable

    2,500–5,000 W, with enough starting power for 3,400 W

Where this lands
  1. Small inverterUp to 2,500 W
  2. This guide
    Mid portable2,500–5,000 W
  3. Large portable5,000–10,000 W
  4. Home standby10 kW and up

Before you plug in

  • Outdoors only, 20 feet away

    Carbon monoxide kills. At least 20 feet from windows, doors and vents — never in a garage.[4][5]

  • Never plug into a wall outlet

    Backfeeding can kill you and utility line workers.[6][3]

  • Use an electrician

    Transfer switches and interlocks are installed by a qualified electrician.[3]

Questions

What size generator do I need to run 2 refrigerators?

Add both refrigerators’ running watts, then add the startup surge of just one — they won’t start in the same second. The “Two refrigerators” line on this page has the numbers.

Do the fridge and freezer have to run at the same time?

They switch themselves on, so plan for both running together. To save fuel, run the generator a few hours at a time and keep the doors shut in between.[2]

Does a deep freezer use a lot of power?

A chest (deep) freezer is one of the lighter motor loads in a house: a small compressor that cycles on and off. Its short startup surge is what the generator has to cover.

Sources

  1. U.S. Department of Energy, Motor Systems Tip Sheet #10: Turn Motors Off When Not in Use
  2. CDC, Keep Food Safe After a Disaster or Emergency
  3. OSHA, Using Portable Generators Safely (Fact Sheet)
  4. CDC, Carbon Monoxide Poisoning Basics
  5. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center
  6. U.S. Consumer Product Safety Commission, Safety Alert: Portable Generator Hazards